CHEN Ling, WU Fangfang, MA Heng, WANG Lifeng, WEI Yili, GAO Yibo
Zhejiang Huadian Equipment Testing Institute, National Safety Performance Quality Supervision & Inspection Center for Electrical Equipment, Hangzhou 310015, China
Abstract:Along with the economic globalization, environmental protection and green energy become the focus of overall construction. Fiber reinforced polymer (FRP) is proved to have excellent properties, such as light weight, high strength, corrosion resistance, insulation and environmental. It has been widely used in electric power networks worldwide. By searching the latest studies and applications, and combining working experiences, the authors overview the applications of FRP in electric power networks from the aspects of composite insulators, FRP towers, FRP electric power fittings, aluminum conductor carbon fiber reinforced core, electrical safety tools and so on. The overview shows that FRP, being of good quality, can satisfy both energy conservation and environment protection requirements. It has great potential in the future.
[1] 冯鹏, 陆新征, 叶列平. 纤维增强复合材料建设工程应用技术—试验、 理论与方法[M]. 北京: 中国建筑工业出版社, 2011. Feng Peng, Lu Xinzheng, Ye Lieping. Application of fiber reinforced polymer in construction: experiment, theory and methodology[M]. Beijing: China Architecture & Building Press, 2011.
[2] 林超. 玻璃钢在电力工业中的应用[J]. 应用能源技术, 2008(11): 36-38. Lin Chao. The application of FRP in electric power industry[J]. Applied Energy Technology, 2008(11): 36-38.
[3] 胡良全, 陈新. 电力行业用复合材料的发展[J]. 玻璃钢/复合材料, 2012, 3(20): 91-93. Hu Liangquan, Chen Xin. Development of composite materials in electric power industry[J]. Fiber Reinforced Plastics/Composites, 2012, 3 (20): 91-93.
[4] 郑楠, 朱岸明, 王中阳, 等. 750 kV 输变电工程复合外绝缘应用进展及展望[J]. 电网与清洁能源, 2013, 29(12): 1-10. Zheng Nan, Zhu Anming, Wang Zhongyang, et al. Progress and prospect of application of composite external insulation in the 750 kV power transmission project[J]. Power System and Clean Energy, 2013, 29 (12): 1-10.
[5] 邢琳, 周庆庆, 尚勇, 等. 750 kV 隔离开关用支柱复合绝缘子关键技术研究[J]. 陕西电力, 2014, 42(2): 44-47. Xing Lin, Zhou Qingqing, Shang Yong, et al. Key technology of post composite insulator used in 750kV AC disconnecting switch[J]. Shaanxi Electric Power, 2014, 42(2): 44-47.
[6] 李国尧, 况骄庭, 钱峰. 智能变电站复合材料电缆支架的技术经济性研究[J]. 浙江电力, 2013(5): 19-56. Li Guoyao, Kuang Jiaoting, Qian Feng. Study on technical and economical efficiency of composite cable supports in intelligent substations[J]. Zhejiang Electric Power, 2013(5): 19-56.
[7] 史传卿, 郑思国. 高强度复合材料电力电缆支架技术性能研究[J]. 供用电, 2011, 28(2): 61-63. Shi Chuanqing, Zheng Siguo. The technical performance research on the electric cable rack made with high strength composite[J]. Distribution & Utilization, 2011, 28(2): 61-63.
[8] 吴正清. 变电站复合电缆支架应用研究[J]. 电工技术: 理论与实践, 2015(4): 175-176. Wu Zhengqing. Application research of composite cable support in substation[J]. Electric Engineering: Theory and Practice, 2015(4): 175-176.
[9] 肖云骧, 邹文治. 非金属箱式变电站箱体的制造工艺[J]. 电气制造, 2008(9): 62-64. Xiao Yunxiang, Zou Wenzhi. Manufacturing process of packaged substation[J]. Electrical Manufacturing, 2008(9): 62-64.
[10] 安利强, 赵东东, 默增禄, 等. 纤维增强复合材料输电杆塔研究进展[J]. 智能电网, 2014, 2(5): 38-45. An Liqiang, Zhao Dongdong, Mo Zenglu. Recent progress of fiber reinforced polymer composite materials transmission poles and towers[J].Smart Grid, 2014, 2(5): 38-45.
[11] 于吉波, 吴雄. 输电用玻璃纤维复合材料杆塔技术开发及应用[J]. 玻璃纤维, 2013(6): 40-47. Yu Jibo, Wu Xiong. Development and application of GRP poles for power transmission[J]. Fiber Glass, 2013(6): 40-47.
[12] 黄汉良, 张子超, 林锋. 我国输配电线路复合材料杆塔的应用现状[J]. 玻璃钢/复合材料, 2014(3): 66-70. Huang Hanliang, Zhang Zichao, Lin Feng. The applied study for the composite pole and tower of domestic transmission line[J]. Fiber Reinforced Plastics/Composites, 2014(3): 66-70.
[13] 柳伟钧, 张锦南, 王强华. 复合材料杆塔技术和应用现状[J]. 玻璃钢/ 复合材料, 2014(6): 76-82. Liu Weijun, Zhang Jinnan, Wang Qianghua. Composite pole & tower technology and application status[J]. Fiber Reinforced Plastics/Composites, 2014(6): 76-82.
[14] Okamoto H. Application of Fiber glass plastics to overhead towers in Japan[R]. New Orleans: IEEE Summer Power Meeting, 1966.
[15] 左玉玺, 薛更新, 孙强, 等. 750 kV输电线路复合横担设计研究[J].电网与清洁能源, 2013, 29(1): 1-8. Zuo Yuxi, Xue Gengxin, Sun Qiang, et al. Research on the design of composite cross arm for 750kV transmission line[J]. Power System and Clean Energy, 2013, 29(1): 1-8.
[16] 龚靖, 张恩铭, 曹帅, 等. 110 kV高性能纤维增强复合材料输电杆塔设计[J].水电能源科学, 2002, 30(10): 161-163. Gong Jing, Zhang Enming, Cao Shuai, et al. Design of 110 kV high performance fiber reinforced composite material transmission poles and towers[J]. Water Resources and Power, 2002, 30(10): 161-163.
[17] 电力输送用新型复合材料杆塔[J]. 电力建设, 2012(10): 119. New type of composite transmission poles and towers[J]. Electric Power Construction, 2012(10): 119.
[18] 刘泽洪. 复合绝缘子使用现状及其在特高压输电线路中的应用前景[J]. 电网技术, 2006, 30(12): 1-6. Liu Zehong. Present situation and prospects of applying composite insulators to UHF transmission lines in China[J]. Power System Technology, 2006, 30(12): 1-6.
[19] 宿志一, 范建斌. 复合绝缘子用于高压及特高压直流输电线路的可靠性研究[J]. 电网技术, 2006, 30(12): 16-23. Su Zhiyi, Fan Jianbin. Research on reliability of composite insulators used in EHV and UHV DC transmission lines[J]. Power System Technology, 2006, 30(12): 16-23.
[20] 巢亚锋, 王成, 黄福勇, 等. 中国输电线路复合绝缘子运行状况分析[J]. 高压电器, 2015, 51(8): 119-124. Chao Yafeng, Wang Cheng, Huang Fuyong, et al. Assessment on operation state of composite insulators used on Chinese Transmission Lines[J]. High Voltage Apparatus, 2015, 51(8): 119-124.
[21] 魏晗兴. 碳纤维复合材料导线芯的制备及其特性研究[D]. 济南: 山东大学, 2010. Wei Hanxing. The preparation and investigation of carbon fiber reinforced composites core[D]. Jinan: Shandong University, 2010.
[22] 何州文, 陈新, 王秋玲, 等. 国内碳纤维复合芯导线的研究和应用综述[J]. 电力建设, 2010, 31(4): 90-93. He Zhouwen, Chen Xin, Wang Qiuling, et al. Research and application overview of ACCC conductor in China[J]. Electric Power Construction, 2010, 31(4): 90-93.
[23] 尤传永. 架空输电线路新型复合材料合成导线的开发研究[J]. 电力建设, 2004, 25(11): 1-6. You Chuanyong. Development of new-type composite conductor for overhead transmission lines[J]. Electric Power Construction, 2004, 25 (11): 1-6.
[24] 李磊, 陈伟, 万建成. 碳纤维复合材料芯导线在国内推广应用的技术经济分析[J]. 电力建设, 2012, 33(9): 79-82. Li Lei, Chen Wei, Wan Jiancheng. Technical and economic analysis on popularization and application of conductor with reinforced core of carbon fiber in China[J]. Electric Power Construction, 2012, 33(9): 79-82.
[25] 杨韬, 马庆强. 新一代复合导线—ACCR 的特点及应用[J]. 电力设备, 2007, 8(12): 84-87. Yang Tao, Ma Qingqiang. Introduction on features and applications of applications of ACCR composite conductor[J]. Electrical Equipment, 2007, 8(12): 84-87.
[26] 何冰, 侯晓明, 王诗策, 等. ACCR导线应用于线路增容工程的问题分析及解决方案[J]. 上海电力, 2008(2): 158-162. He Bing, Hou Xiaoming, Wang Shiche, et al. Analysis and solution of ACCR wire applied in line capacity increasing project[J]. Shanghai Electric Power, 2008(2): 158-162.
[27] 马庆强. 复合导线ACCR的特点及冰雪环境下的应用[J]. 中国电力, 2008, 41(11): 77-79. Ma Qingqiang. Intruction on features and iced area application of ACCR composite conductor[J]. Electric Power, 2008, 41(11): 77-79.
[28] 瞿业明, 张伟, 葛乐. 玄武岩纤维在输电线路中的应用探讨[J]. 电工技术, 2010(12): 14-19. Qu Yeming, Zhang Wei, Ge Le. Discussion on application of basalt fiber in transmission line[J]. Electric Engineering, 2010(12): 14-19.
[29] 方健银, 张开拓. 绞合型碳纤维复合芯软型铝绞线及其应用[J]. 电世界, 2014(9): 449-452. Fang Jianyin, Zhang Kaituo. Twisted type carbon fiber composite core aluminum stranded and its application[J]. Electric World, 2014, 9: 449-452.
[30] 吴雄文, 陈创, 陈泽师, 等. 绞合型碳纤维芯导线的性能及施工工艺研究[J]. 中国电业: 技术版, 2014(4): 58-61. Wu Xiongwen, Chen Chuang, Chen Zeshi, et al. Research of characteristic and construction technology of hinged type carbon fiber core line[J]. China Electric Power: Technology Edition, 2014(4): 58-61.
[31] 梁栋, 邓蜀平, 蒋云峰, 等. 碳纤维复合芯电缆国内外技术研发现状及工程应用进展[J]. 化工新型材料, 2011, 39(4):1 3-17. Liang Dong, Deng Shuping, Jiang Yunfeng, et al. Situation of technology research and engineering application for aluminum conductor composite core reinforced cable[J]. New Chemical Materials, 2011, 39(4): 13-17.
[32] 程云堂, 钱尼华, 陈韶昱, 等. 复合材料电力金具能耗仿真与试验[J]. 浙江电力, 2015(1): 27-30. Cheng Yuntang, Qian Nihua, Chen Shaoyu, et al. Analysis on simulation and test of energy consumption of composite power fittings[J]. Zhejiang Electric Power, 2015(1): 27-30.
[33] 牛海军, 付斌, 朱宽军. 改性复合材料间隔棒和悬垂线夹的研制及应用[J].电力建设, 2014, 35(6): 97-101. Niu Haijun, Fu Bin, Zhu Kuanjun, Development and application of spacer and suspension clamp based on modified composites[J]. Electric Power Construction, 2014, 35(6): 97-101.
[34] 余虹云, 俞成彪, 李瑞. 电力安全工器具及小型施工机具[M]. 北京: 中国电力出版社, 2008. Yu hongyun, Yu Chengbiao, Li Rui. Electrical safety tools and small construction machinery[M]. Beijing: China Electric Power Press, 2008.
[35] 国家能源局. DL/T 1209.1—2013 变电站登高作业及防护器材技术要求, 第1部分:抱杆梯、梯具、梯台及过桥[S]. 北京: 中国电力出版社, 2013. National Energy Administraion. DL/T 1209.1—2013 Specifications for substation ascending operation and protective device, Part 1:holding bar ladder, ladder utensil, ladder platform and bridge[S]. Beijing: China Electric Power Press, 2013.
[36] 国家能源局. DL/T 1209.2—2014 变电站登高作业及防护器材技术要求, 第2部分:拆卸型检修平台[S]. 北京: 中国电力出版社, 2014. National Energy Administraion. DL/T 1209.2—2014 Specifications for substation ascending operation and protective device, Part 2: demountable maintenance platform[S]. Beijing: China Electric Power Press, 2014.
[37] 国家能源局. DL/T 1209.3—2014变电站登高作业及防护器材技术要求, 第3部分:升降型检修平台[S]. 北京: 中国电力出版社, 2014. National Energy Administraion. DL/T 1209.3—2014Specifications for substation ascending operation and protective device, Part 3:lift maintenance platform[S]. Beijing:China Electric Power Press, 2014.
[38] 国家能源局. DL/T 1209.4—2014变电站登高作业及防护器材技术要求, 第4 部分:复合材料快装脚手架[S]. 北京: 中国电力出版社, 2014. National Energy Administraion. DL/T 1209.3—2014 Specifications for substation ascending operation and protective device, Part 4:lift maintenance platform[S]. Beijing: China Electric Power Press, 2014.
[39] 李兆广, 刘俊勇. 500kV V型复合绝缘子串芯棒断裂事故分析[J]. 广东电力, 2009, 22(11): 70-72. Li Zhaoguang, Liu Junyong. Analysis of core rod fracture fault of 500kV V-shaped composite insulator string[J]. Guangdong Electric Power, 2009, 22(11): 70-72.
[40] 应伟国. 棒形悬垂复合绝缘子芯棒脆断的原因及预防对策[J]. 电力设备, 2005, 6(10): 38-40. Ying Weiguo. Case study and prevention countermeasures of core stick crisp and broken for rod suspension composite insulator[J]. Electrical Equipment, 2005, 6(10): 38-40.
[41] 卢明, 胡文, 李黎, 等. 交流500 kV复合绝缘子芯棒断裂原因分析[J]. 电瓷避雷器, 2015(3): 23-34. Lu Ming, Hu Wen, Li Li, et al.Analysis on the causes of the core rod fracture of 500kV AC composite insulator[J]. Insulators and Surge Arresters, 2015(3): 23-34.
[42] 张志猛, 贾伯岩, 齐胜涛, 等. 220 kV输电线路鸟害故障跳闸原因分析及处理措施[J]. 河北电力技术, 2015, 34(4): 54-56. Zhang Zhimeng, Jia Boyan, Qi Shengtao, et al. Cause analysis and settlement on 220kV transmission line bird dejecta flashover fault tripping[J]. Hebei Electric Power, 2015, 34(4): 54-56.
[43] 杨敏祥, 陈原, 李卫国, 等. 复合材料杆塔研究现状及关键技术问题[J]. 华北电力技术, 2010(10): 48-50. Yang Minxiang, Chen Yuan, Li Weiguo, et al. Research progress on composite tower and pole and its key technical problems[J]. North China Electric Power, 2010(10): 48-50.
[44] 任宗栋, 刘泉, 默增禄. 纤维增强复合材料输电杆塔节点设计及优化[J]. 电力建设, 2011, 32(4): 87-91. Ren Zongdong, Liu Quan, Mo Zenglu. Joint design and optimization of FRB tower[J]. Electric Power Construction, 2011, 32(4): 87-91.
[45] 李瑞, 余虹云, 余长水, 等. ACCC导线芯棒高温“竹节”现象浅析[J]. 电力建设, 2008, 29(6): 22-25. Li Rui, Yu Hongyun, Yun Changshui, et al.Discussion on the "Bamboo Knot" phenomena of ACCC cable under high temperature[J]. Electric Power Construction, 2008, 29(6): 22-25.