In order to correct the field frequency deviation caused by the machining error and the welding shrinkage in the manufacturing process of the multi-cell medium β SRF cavity, a regulating mechanism-warm tuner is designed based on the multicell medium β SRF cavity's characteristics and the field flatness principle. The tuner contains five parts, which are the activity carriage, the gearbox carriage, the tailstock, the activity tailstock and the bed body. The warm tuner is used in the test of the field flatness and the field frequency of a medium β SRF cavity. Finally, the test system of the RF superconducting cavity field flatness is set, detailed analyses and designs of the bead-pulling system, the network analyzer and the microcomputer control system are carried out. The microcomputer control system uses the virtual instrument Lab VIEW software as the platform to control the other parts in the test system, and to analyze the test results, to present the test results. The results show that the medium β SRF cavity warm tuner can be successfully used for the test and modulation.
ZHANG Xinrong
,
XUE Peipei
,
ZHANG Liping
,
SUN An
. The Design and Test of the Warm Tuner for Multi-Cell Medium β SRF Cavity[J]. Science & Technology Review, 2014
, 32(18)
: 54
-57
.
DOI: 10.3981/j.issn.1000-7857.2014.18.008
[1] 温华明, 严陆光, 林良真. 超导在加速器中的应用概况[J]. 低温与超 导, 2005, 33(1): 46-49. Wen Huaming, Yan Luguang, Lin Liangzhen. Superconducting application in the accelerator[J]. Cryogenic and Superconducting, 2005, 33(1): 46-49.
[2] Gao C Y. PEFP SRF low-bate elliptical cavity tuning[D]. Korea: Korea University of Science and Technology, 2008.
[3] 孙安. 中β质子超导射频腔腔形研究[D]. 北京: 中国科学院高能物理 研究所, 2002. Sun An. The research of the medium β RF superconducting cavity's shape[D]. Beijing: Beijing Academy of Sciences Institute of High Energy Physics, 2002.
[4] Sun A, Wang H P, Wu G F. Effect of the tuner on the field flatness of SNS superconducting RF cavities[J]. Proceedings of LINAC, 2004, 815.
[5] Zhang L P, Sun A, Li Y M, et al. Control and measurement system for the tuning of a PEFP low-beta superconducting RF cavity[J]. Journal of the Korean Society, 2009, 54(5): 2025-2030.
[6] 王立新. 软件测试数据的高效生成及测试方法研究[D]. 上海: 东华大 学, 2011. Wang Lixin. Study on the method of software test data efficiently generate and test[D]. Shanghai: Donghua University, 2011.
[7] 孙伟. 软件测试技术发展模式探讨[J]. 长春理工大学学报, 2012, 7 (4): 235-236. Sun Wei. Software testing technology development model[J]. Journal of Changchun University of Science and Technology, 2012, 7(4): 235-236.
[8] 王杰, 程明远, 李士晓. 浅谈机械设计加工中应注意的几个问题[J]. 机 械与电子, 2011(11): 512-513. Wang Jie, Cheng Mingyuan, Li Shixiao. Discussion on several problems of mechanical design process[J]. Mechanical and Electronic, 2011(11): 512-513.
[9] 朱凤, 全胜文, 徐文灿, 等. 北京大学光阴极注入器3+1/2超导腔机械 性能[J]. 强激光与离子束, 2007, 19(8): 1361-1364. Zhu Feng, Quan Shengwen, Xu Wencan, et al. Mechanical properties of 3+1/2 cavity of PKU photo-injector[J]. High Power Laser and Particle Beams, 2007, 19(8): 1361-1364.
[10] Ginzton E L. Microwave measurements[M]. New York: McGraw-Hill Book Company, 1957.